Wall Mount AC/DC Adapter
No: 12V Adapter, ac adapter, dc adapter, power adapter, ac/dc adapter

SPECIFICATIONS

Merryking has 14 Years ac/dc power adapter manufacturing experience.

A DETAILED FORM


Basic Info



Model NO.: MKS-A241-1202000S                                          HS Code: 85044019

Input Voltage: 90VAC~264VAC                                            Efficiency: 86.20%Min.@ Nominal Input



Product Description

24W ac dc power adapter with 2 years warranty :

1. AC/DC Power Adapter Specification :

 
Model.: Output Voltage.: Output Current.: Watt (W)
MKS-0503000 5.00V 3.00A 15.0W
MKS-0603000 6.00V 3.00A 18.0W
MKS-0753000 7.50V 3.00A 22.5W
MKS-0902500 9.00V 2.50A 22.5W
MKS-1202000 12.0V 2.00A 24.0W
MKS-1501600 15.0V 1.60A 24.0W
MKS-1801200 18.0V 1.20A 21.6W
MKS-2401000 24.0V 1.00A 24.0W
MKS-4800500 48.0V 0.50A 24.0W


 





2. SCOPE

The document detail the electrical, mechanical and environmental specifications of a SMPS, the power supply provide 24W
continuous output power.
The power supply shall meet the RoHS requirement.

2.1 Description :
SMPS Adaptor(Wall mount)


3. Input Characteristics of 24W power adapter 
3.1  Input Voltage & Frequency:
The range of input voltage is from 90Vac to 264Vac single phase

 

Type. Minimum Nominal Maximum
Input Voltage. 90Vac 100Vac~240Vac 264Vac
Input Frequency. 47Hz 60Hz/50Hz 63Hz
3.2.  Input AC Current/AC:
0.8Amax. @ 100-240Vac input & Full load
3.3.  Inrush Current (cold start):
40Amax. @ 264Vac input
3.4.  Average Efficiency: 
86.20%min.Nominal input
3.5.  Energy Consumption : ≤0.1W

4.   Output Characteristics of 24W dc adapter 
4.1  Static Output Characteristics <Vo & R+N>
Output Rated Load Output Range R+N Remark
Rate Min. Load Max. Load
+12V 0.0A 2A 11.4V~12.6V 120mVp-p  

Ripple & Noise: Measurement is done by 20MHz bandwidth oscilloscope and the output paralleled a 0.1uF ceramic
capacitor and a 10uF electrolysis capacitor. (test under the condition of rated input and rated output)

4.2  Line/ Load Regulation:
Output Load Condition Line Regulation Load Regulation Remark
Rate Min. Load Max. Load
+12V 0.0A 2A +/-1% +/-5%  


4.3  Turn - on Delay Time
3S 
max. @ 100Vac to 240Vac input & Full load

4.4  Hold-up Time
10mS 
min. @ Full load &115Vac/60Hz input turn off at worst case
20mS min. @ Full load &230Vac/50Hz input turn off at worst case

4.5  Rise Time
20mS max. @ Rated load
4.6  Fall Time
20mS max. @ Full load
4.7  Output Overshoot / Undershoot

10% max. When the power on or off
4.8  Output Load Transient Response

Output voltage within 11.4V~12.6V for load step from 25% to 50% to 25%,50% to 75% to 50%
R/S: 0.25A/uS, Transient Response Recovery Time :200uS,Dynamic response overshoot 5%

5.   Protection Requirements of 24W power adapter 

5.1 Over Current P
rotection:
The output shall hiccup when the over currents applied to the output rail, and shall be self-recovery
when the fault condition is removed

5.2  
Short Circuit Protection:
The input power shall decrease when the o
utput rail short, the power supply shall no damage,
and shall be self-recovery when the fault condition is removed


6.  Environment Requirements
6.1  Operating Temperature and Relative Humidity:
0ºC to +40ºC
10%RH to 90%RH

6.2  
Storage Temperature
 and Relative Humidity:
-20ºC to +80ºC
5%
RH to 95%RH non-condensing @ Sea level shall be low 2,000 meter

6.3  Vibration:

10 to 300Hz sweep at a constant acceleration of 1.0G(Breadth: 3.5mm) for 1Hour for each of the
perpendicular axes X, Y, Z

6.4  
Drop in:
1 Corner, 3 Edges, 6 Surfaces, Height: 100cm, On the Boards plane, the plug can be bend, and  
scratch, but the structure should not be damaged, and can work normally


7.   Reliability Requirements
7.1  Burn-in:
The power supply shall be burn-in for 4 Hours under normal input and 80% rated load at 40ºC5ºC

8.     EMI/EMS Standards/EMI/EMS
7.1   EMI Standards/EMI: EN55014
7.2   
EMS Standards/EMS:

7-2-1 EN 61000-4-2,electrostatic discharge(ESD) requirement
7-2-2 EN 61000-4-3,radiated electromagnetic field susceptibility(rs)
7-2-3 EN 61000-4-4,electric fast transients(burst) immunity requirement
7-2-4 EN 61000-4-5,surge capability requirement
7-2-5 EN 61000-4-6, Induced radio frequency fields conducted disturbances immunity requirement

9.   Safety Standards
9.1  Dielectric Strength(Hi-pot):
Primary to Secondary3000Vac / 10mAMax / 60 second

9.2   
Leakage Current:
0.
25mAmax. at 264Vac 50Hz

9.3  
Insulation Resistance:

50MΩ min. at primary to secondary add 500Vdc test voltage

9.4  
Regulatory
 Standards :
Type. Country. Standard. State. Note.
UL/cUL USA/Canada UL60950 PASS  
FCC-EMC USA/Canada Part15 Class B PASS  
CE/GS/CB Europe EN61558 PASS  
CE-EMC Europe EN55014 PASS  


11.    DC Wire of Adapter : 
UL2464 20AWG L=1.5m or 1.8m 
OEM&ODM

12.   Package of dc adapter :  1PC/White Box 

QTY: 96PCS

N.W.: 8.5KGS

G.W.: 9.6KGS

MEAS.: 40.5x37.5x23.5cm



13.  About Merryking Factory  :


(1) OUR WORKSHOP:

In Merrykings workshop, some key production processes have used machines instead of human labor, 

which can improve production efficiency and ensure product quality.





(2) OUR R&D TEAM:

We have the most experienced R&D team: structural engineer, electronics engineer, safety standard engineer, 

packaging design engineer and technical engineer.





(3) OUR PRODUCT TEST :

We have a strict quality control system, starting with  IPQC testing of raw materials, to different functional devices testing on production line. In the end, QA do the last testing based on the AQL standard before the final shipment.



(4) OUR PROFESSIONAL SALES TEAM:

We have the most dynamic post-90s sales team.
Focusing on teamwork spirit, we serve customers with professionalism and positive attitude



More info welcome send us email.  thanks 

Enjoy work with us!

SEND YOUR MESSAGE TO MERRYKING ADAPTER FACTORY

To: Nikki Xiang

Message:

your message bust be between 20-8000 characters

For better quotations, include: - A self introduction - Special requests, if any
Quantity:

We will reply to you within 24 hours